Reliability and redundancy and energy efficiency were critical when eBay selected the fire and life safety systems for its new Tier IV level data center in South Jordan, Utah. Because maintaining and operating this $287 million data center is an absolute necessity, fire and life safety systems help meet the important goal of continuous operation and mission continuity. The fire and life safety system design complexities were handled by Schmid & Associates, P.C. Fire Protection Engineers of Maryland.

The master plan for the site breaks down into four phases, which will allow eBay to consolidate leased data center space currently spread across three states. The first phase of the project is a 240,000 sq. ft. building housing three 20,000 sq. ft. data center halls — one for eBay Marketplace, one for PayPal.com, and a third for expansion space.

The fire and life safety system design was specified to use 50 percent capacity loads, which coincides with eBay wanting to achieve high levels of redundancy while using as much as 50 percent less energy than other facilities that it leases. For the fire and life safety system, this was achieved using several loops, which increased programming.

Getting the system up and running was awarded to Fire Protection Service, Mountain Alarm of Ogden, Utah. “The new eBay data center requires reliable and redundant fire protection. The unique requirements demand much more, especially in the generator rooms and four chiller plants,” said Boyd Ferrin, general manager for the fire side of Mountain Alarm.

Mountain Alarm utilized System Sensor and NOTIFIER products, including early-warning laser smoke detectors that can provide warning of incipient fires before disaster strikes to duct smoke detectors and addressable photoelectric smoke detectors all networked to three NOTIFIER NFS2-3030 panels. So far there are 1,370 laser smoke detectors, 399 photoelectric smoke detectors, 253 horn strobes, 130 strobe devices, 40 horn devices, as well as pull stations and monitoring relay modules installed. Even the several hundred track units are networked into the panels for complete localized monitoring.

Did you enjoy this article? Click here to subscribe to SDM Magazine. 

You must login or register in order to post a comment.

Multimedia

Videos

Image Galleries

Podcasts

Scott Barrett, president and founder of CWSI, discusses wireless technology advancements in the podcast, “5 Secrets of Wireless Addressable Fire Systems."

More Podcasts

Workplace recycling

Workplace recycling can save money on supplies, conserve natural resources, reduce waste disposal costs and better position your company as an environmentally-conscious business. Where is your company at?
View Results Poll Archive

THE MAGAZINE

SDM Magazine

may cover

2013 May

The May edition highlights the 23rd SDM 100 Report which features the top 100 companies who have put security-as-a-service into action. Also featured in this edition, State of the Market: Access Control.
Table Of Contents Subscribe

Clear Seas Research

Clear Seas logoWith access to over one million professionals and more than 60 industry-specific publications, Clear Seas Research offers relevant insights from those who know your industry best. Let us customize a market research solution that exceeds your marketing goals.

THE SDM STORE

SDM Top Systems Integrators Report
2010 Top Systems Integrators Report
The SDM Top Systems Integrators Report ranks, by total annual revenue, the largest U.S. firms that contract electronic security projects for commercial, industrial, institutional, government, and other non-residential markets.
More Products

SDM Green Page

Green leaves

Click here to visit the SDM Green page!

STAY CONNECTED

Facebook logo 40px 2-12-13 Twitter logo 40px 2-12-13  YouTube logo 40px 2-12-12  LinkedIn logo 40px 2-12-13