SDMmag logo
search
Go to Ask SDM AI
cart
facebook twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
SDMmag logo
  • NEWS
  • PRODUCTS
  • TOPICS
    • Access Control & Identification
    • Integration & Network Solutions
    • Life Safety & Fire Alarm
    • Monitoring
    • Smart Home
    • Trends & Industry Issues
    • Video Solutions
  • COLUMNS
    • Digital Shuffle
    • Editor's Angle
    • Insider News & Business
    • Integration Spotlight
    • Marketing Madmen
    • Security & the Law
    • Security Comings & Goings
    • Security Networkings
    • Technology @ Work
    • Technology Solutions & Skills
    • SIA Waypoints
    • Cybersecurity Chronicle
  • EXCLUSIVES
    • Annual Industry Forecast
    • Dealer of the Year
    • Project of the Year
    • SDM 100
    • State of the Market Series
    • Systems Integrator of the Year
    • Top Systems Integrator Report
    • TMA Excellence Awards
  • BLOG
  • MEDIA
    • Videos
    • Podcasts
    • Polls
    • White Papers
  • EVENTS
    • Industry Calendar
    • Webinars
  • MORE
    • Classified Ads
    • Newsletters
    • SDM Store
    • State of Security eBook
    • Sponsored Insights
  • BUYERS GUIDE
    • Buyers Guide
    • Take a Tour
  • EMAG
    • eMagazine
    • Archive Issues
    • Monitoring Today
    • Advertise
  • SIGN UP!

Point A to Point B

June 1, 2004

Questions

1. Category 3 cable is rated to support what maximum data transmission speed?

a. 1 MHz

b. 16 MHz

c. 20 MHz

d. 100 MHz

e. 200 MHz

2. Category 5 cable is rated to support what maximum data transmission speed?

a. 1 MHz

b. 16 MHz

c. 20 MHz

d. 100 MHz

e. 200 MHz

3. Category 6 cable is rated to support what maximum data transmission speed?

a. 1 MHz

b. 16 MHz

c. 20 MHz

d. 100 MHz

e. 200 MHz

4. The type 66 punch down block

is recommended for termi- nation of category 6 cables.

a. True

b. False

5. A wiremap tester will check a cable for

a. opens/shorts.

b. crossed pairs.

c. reversed pairs.

d. split pairs.

e. All of the above

6. A time domain reflectome- ter is often used to test cable length.

Looking for quick answers on security topics? Try Ask SDM, our new smart AI search tool. Ask SDM →

a. True

b. False

7. A data cable problem that couples so much of the signal being transmitted back on the receive pair that incoming signals can be unintelligible is called

a. attenuation.

b. impulse noise.

c. near-end crosstalk.

d. None of the above

8. A frequency of 1 billion cycles per second is represented as

a. 1 KHz.

b. 1 MHz.

c. 1 GHz.

d. 1 BHz.

9. What is the AWG size of the center conductor in an RG-6U cable?

a. 6

b. 12

c. 18

d. 24

10. All RG-6U cables are identical in construction.

a. True

b. False

11. All cables installed above a drop ceiling must be plenum-rated.

a. True

b. False

12. When running data cables you should avoid

a. electrical power lines.

b. fluorescent lights.

c. electrical equipment.

d. All of the above

13. Which of the following AWG wires has the highest current-carrying capacity?

a. 6

b. 12

c. 18

d. 24

14. When installing category 6 cables you should avoid

a. sharp bends.

b. pulling too hard on the cable.

c. pinching the cable with staples or ty-raps.

d. All of the above

Point A to Point B

Not all cables are created equally. Many applications require special cables that are designed to meet the requirements of current flow, frequency, or data rates. For this reason it is important that you match the correct cable to the job, because failure to do so can result in improper operation, damaged equipment, or wasted resources.

To check your understanding of when to use various types of cables, take the following quiz.

What’s Wrong with This?

Wally ‘Larman installed cabling for telephony and data communications for a small commercial client along with a burglary/fire alarm system. He used category 5e cables that were specified by his client for the telephony/data runs and properly installed them throughout the space. He carefully installed the termination equipment and tested each cable. He then connected the existing POTS line for the FAX machine as shown in this diagram, but as often happens with Wally’s work, when he was finished the FAX machine did not work. Can you see what Wally did wrong and how to correct his mistake?

Answers

1. b

2. d

3. e

4. b – In the past, the type 66 punch-down block was commonly used for telephony connections, but when using category 6, or similar data cables, if a punch down block is necessary, the 110 punch down block is recommended.

5. e

6. a – The time domain reflectometer also will locate impedance mismatches.

7. c – Near-end crosstalk (NEXT) is induced crosstalk measured at the end near the transmitter. Far-end crosstalk (FEXT) is crosstalk measured at the far end of the cable.

8. c – 1 KHz is 1 thousand cycles per second; 1 MHz is 1 million cycles per second. The expression 1 BHz does not exist.

9. c

10. b – RG-6U cables can differ in many ways, such as percentage of overall shielding and composition of shield (aluminum or copper) or composition of center conductor (solid copper or copper-covered steel). In addition there are RG-6U cables that are called quad shield, which have two sets of foil/braided shields.

11. b – Although you should check local codes, typically plenum-rated wire is only needed if the air space above the drop ceiling is used as an air plenum.

12. d

13. a

d – All of these actions can distort the cable, adversely affecting its parameters. In addition, when making connections you should only use connectors with the appropriate rating and not untwist the wires any more than absolutely necessary.

Answer to: What’s Wrong with This?

Wally’s problem is caused by the way he connected the old POTS wires to the category 5e cable. The old standard POTS telephone color code places the Ring (-) and Tip (+) on the Red and Green wires, which should be connected to pair #1, the blue/white pair of the category 5e cable on pins 3 and 4. The way Wally connected the wires the POTS line for the FAX machine was split between the white/orange wire and the blue/white wires. Wally should re-wire the cables as shown in this diagram and then test the FAX machine. It is important whenever working on older equipment that you understand the wiring conventions that were used and that you should check all terminations and cables before connecting any equipment.

Correction:

EOL Should Be in Series, Not Parallel SDM inadvertently published a diagram containing an error (SDM, April 2004 “5-Minute Tech Quiz Answers,” p. 87.) Due to an error in composing the art work for the diagram, the connections for the power supervisory relay were inadvertently shown as connected in parallel with the EOL resistor when they should have been shown in series. By connecting the relay in series, an interruption in power will cause an open in the initiating circuit, which will be recognized as a trouble condition by the control. The corrected diagram is shown here. SDM regrets any inconvenience that this might have caused, and thank our subscribers for bringing this to our attention.

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • SDM 100

    SDM 100: Top 100 Security Dealers of 2026

    The top 100 security dealers navigated a complex...
    Exclusives
    By: Karyn Hodgson
  • Security camera

    State of the Market: Video Surveillance

    As video surveillance shifts from siloed systems to...
    State of the Market Series
    By: Brianna Wilson
  • 2026 Industry Forecast

    SDM 2026 INDUSTRY FORECAST

    Rapid technology advances meet shifting economic...
    Trends & Industry Issues
    By: Karyn Hodgson
Manage My Account
  • SDM Newsletters
  • Online Registration
  • eMagazine Subscriptions
  • Subscription Customer Service
  • Manage My Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the SDM audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of SDM or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Doctor examining child patient with mother present in medical clinic
    Sponsored byHID

    The Human Side of Hospital Security: How Modern Visitor Management Protects People First

Popular Stories

ESA Board of Directors Q2 26 Elections

Electronic Security Association Announces 2026 Board of Directors Election Results

TMA & SDM Logos

Becklar, Elite & Puget Win 2026 TMA/SDM Monitoring Center Excellence Awards

SDM 100 of 2026

The 2026 SDM 100 Top Brand Choices

SDM Dealer of the Year 2026 Promotion

Poll

What’s the most promising trend in the industry?

What’s the most promising trend in the industry?
View Results Poll Archive

Products

Physical Security Assessment Handbook An Insider’s Guide to Securing a Business

Physical Security Assessment Handbook An Insider’s Guide to Securing a Business

See More Products
SDM 100 2026 Rankings

Related Articles

  • DITEK_installed

    Practical Advice for Getting Surveillance Video From Point A to Point B

    See More
  • Point-to-Point Solution Connects Ethernet Technology to Existing Coaxial Installations

    See More
  • CannaGuard Video Solution - SDM

    Cloud Video Solution Helps Protect Cannabis Industry From Seed to Point-of-Sale

    See More

Related Products

See More Products
  • security culture.webp

    Security Culture: A How-to Guide for Improving Security Culture and Dealing with People Risk in Your Organisation

  • A Leaders Guide Book Cover_Nicholson_29Sept2023.jpg

    A Leader’s Guide to Evaluating an Executive Protection Program

  • physical security.webp

    Physical Security Assessment Handbook An Insider’s Guide to Securing a Business

See More Products
×

Be in the forefront of security intelligence when you receive SDM.

Join over 10,000+ professionals when you subscribe today.

SIGN UP TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • Newsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing