SDMmag logo
search
Go to Ask SDM AI
cart
facebook twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
SDMmag logo
  • NEWS
  • PRODUCTS
  • TOPICS
    • Access Control & Identification
    • Integration & Network Solutions
    • Life Safety & Fire Alarm
    • Monitoring
    • Smart Home
    • Trends & Industry Issues
    • Video Solutions
  • COLUMNS
    • Digital Shuffle
    • Editor's Angle
    • Insider News & Business
    • Integration Spotlight
    • Marketing Madmen
    • Security & the Law
    • Security Comings & Goings
    • Security Networkings
    • Technology @ Work
    • Technology Solutions & Skills
    • SIA Waypoints
    • Cybersecurity Chronicle
  • EXCLUSIVES
    • Annual Industry Forecast
    • Dealer of the Year
    • Project of the Year
    • SDM 100
    • State of the Market Series
    • Systems Integrator of the Year
    • Top Systems Integrator Report
    • TMA Excellence Awards
  • BLOG
  • MEDIA
    • Videos
    • Podcasts
    • Polls
    • White Papers
  • EVENTS
    • Industry Calendar
    • Webinars
  • MORE
    • Classified Ads
    • Newsletters
    • SDM Store
    • State of Security eBook
    • Sponsored Insights
  • BUYERS GUIDE
    • Buyers Guide
    • Take a Tour
  • EMAG
    • eMagazine
    • Archive Issues
    • Monitoring Today
    • Advertise
  • SIGN UP!

Fire Alarm Monitoring Technology

By Ron Nelson
September 1, 2007


  1. A digital alarm communicator transmitter (DACT) shall seize the telephone line when it is required to transmit a signal.
    a. True
    b. False

  2. A fire alarm system utilizing a DACT shall employ one telephone line and a:
    a. second telephone line.
    b. cellular telephone connection.
    c. approved radio system.
    d. Any of the above
    e. None of the above

  3. What is the minimum number of telephone lines that a digital alarm communicator receiver (DACR) shall have?
    a. 1
    b. 2
    c. 3
    d. 4
    e. 5

  4. What is the time interval in hours that a DACT shall transmit a signal to the DACR?
    a. 1
    b. 12
    c. 24
    d. 36
    e. 48

  5. A DACT shall be programmed to call a second DACR telephone number if unable to connect to the first number.
    a. True
    b. False

  6. Which signal type has the highest priority?
    a. Trouble
    b. Supervisory
    c. Alarm
    d. They all have the same priority.

  7. You cannot use call forwarding for DACR telephone lines.
    a. True
    b. False

  8. Ground start telephone lines are acceptable as the primary telephone line for DACT use.
    a. True
    b. False

  9. What is the maximum time, in seconds, between initiating of an alarm at the protected premises and display at the supervising office?
    a. 30
    b. 60
    c. 90
    d. 120
    e. 200

  10. There is no limit to the number of DACTs that can communicate to a single DACR.
    a. True
    b. False

  11. A single spare DACR can be used as backup to how many active DACRs?
    a. 1
    b. 2
    c. 3
    d. 4
    e. 5

  12. You cannot use WATS or long distance lines for DACR telephone lines.
    a. True
    b. False

  13. The DACR shall supervise the incoming telephone lines for loss of voltage.
    a. True
    b. False

  14. The DACT shall supervise both telephone lines that it is utilizing for transmission of signals to the remote monitoring office.
    a. True
    b. False

  15. How many DACTs can be connected to a DACR that uses two parallel processing telephone lines in a single hunt group?
    a. 50
    b. 100
    c. 500
    d. 1000
    e. 5000


What’s Wrong with This?

Wally `Larman installed a fire alarm system for a commercial customer who had a broadband Internet connection with a voice over Internet protocol (VoIP) telephone line. He verified that the DACT he used could transmit signals using a VoIP telephone line, carefully installed an RJ-31X jack to ensure line seizure, connected the FACP as shown in this diagram, and tested the system. Everything seemed to work OK, but when the local AHJ inspected the installation, he was not satisfied. Can you see what Wally did wrong and what he must do to correct the problem?

5-Minute Tech Quiz Answers

  1. a

  2. d — All DACTs require a second means of communication to ensure that signals can be transmitted to the monitoring office.

  3. b

  4. c — NFPA requires that a DACT transmit a test signal to the monitoring office every 24 hours to ensure operation of the system. If an automation system is employed at the monitoring office, any successful signal transmission during the 24-hour period can fulfill this requirement.

  5. a

  6. c — Alarm signals always have priority over other types of signals.

  7. b

  8. b — Ground start telephone lines are not acceptable because they cannot be properly supervised.

  9. c

  10. b — The maximum number of DACTs that can be connected depends upon the number of telephone lines connected to the DACR and the types of communicators connected to the DACR.

  11. e

  12. b

  13. a — Any failure of an incoming DACR telephone line shall be annunciated visually and audibly at the monitoring office.

  14. a


Answer to: What's Wrong with This?

Wally’s problem is caused by using only one telephone line as a communication path to the remote monitoring office. Wally should connect a POTS line using the public switched telephone network as the primary telephone line and connect the VoIP telephone line as the second communication path as shown in this diagram. As an alternative, Wally may be able to install an approved Internet communication module that can be fully supervised and may not require any telephone lines for communication. Wally should check with the manufacturer of the FACP and the local AHJ to determine if this option is viable. Whenever using VoIP lines, you should verify that the DACT is capable of proper communication and that sufficient battery standby is installed to meet the requirements of the system and the AHJ.

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Contributing Technology Writer. Ron Nelson has more than 36 years' experience in the security industry, and is employed with Mutual Central Alarm Services Inc., New York. He can be reached at sdmtechtips@bnpmedia.com.

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • SDM 100

    SDM 100: Top 100 Security Dealers of 2026

    The top 100 security dealers navigated a complex...
    SDM 100 Report
    By: Karyn Hodgson
  • Security camera

    State of the Market: Video Surveillance

    As video surveillance shifts from siloed systems to...
    State of the Market Series
    By: Brianna Wilson
  • 2026 Industry Forecast

    SDM 2026 INDUSTRY FORECAST

    Rapid technology advances meet shifting economic...
    Annual Industry Forecast
    By: Karyn Hodgson
Manage My Account
  • SDM Newsletters
  • Online Registration
  • eMagazine Subscriptions
  • Subscription Customer Service
  • Manage My Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the SDM audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of SDM or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Doctor examining child patient with mother present in medical clinic
    Sponsored byHID

    The Human Side of Hospital Security: How Modern Visitor Management Protects People First

Popular Stories

Video surveillance camera

Why Video Health Monitoring Is a ‘No Brainer’

ESA Board of Directors Q2 26 Elections

Electronic Security Association Announces 2026 Board of Directors Election Results

TMA & SDM Logos

Becklar, Elite & Puget Win 2026 TMA/SDM Monitoring Center Excellence Awards

SDM Dealer of the Year 2026 Promotion

Poll

What’s the most promising trend in the industry?

What’s the most promising trend in the industry?
View Results Poll Archive

Products

Physical Security Assessment Handbook An Insider’s Guide to Securing a Business

Physical Security Assessment Handbook An Insider’s Guide to Securing a Business

See More Products
SDM 100 2026 Rankings

Related Articles

  • FIELD GUIDE TO MONITORING: Alarm signaling & monitoring: technology overview

    See More
  • Fire Alarm Codes and Standards

    See More
  • New Features for Fire Detection

    See More
×

Be in the forefront of security intelligence when you receive SDM.

Join over 10,000+ professionals when you subscribe today.

SIGN UP TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • Newsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing